The problem with an ‘approximate’ heat calculation done online, is the risk of overpowering the heating needed for each room. Or would you prefer advice, from an experienced electric heating expert? Overheating your home is illegal These heat loads take into account the specific U values provided for each exercise and has been produced as a conservative estimate due to variable geographical emplacement of the properties.Īny online calculator that DOESN’T include all these parameters, is only giving you an approximate guide, and NOT an accurate and reliable answer. Heating load calculations for a well insulated property built after 1976 are based on a requirement for 35/45 watts per M2.

  • Planning for a zonal heating system must start early because the system depends on the efficiency of the building shell and the floor plan.
  • Your personal bespoke heating requirement.
  • Which rooms have a north-facing, exterior wall?.
  • The average external temperature and the thermal zone of your town or city (which is very different for Scotland, coastal towns, inner cities, and rural villages).
  • The construction of the floor and the underfloor construction.
  • What type – and how much – roof insulation is present.
  • HEATING LOAD PER M2 THUMB CODE

  • Is it a single-story building? Postal code location.
  • HEATING LOAD PER M2 THUMB WINDOWS

    Number of internal and external doors, the number of windows with opening lights.Insulation method of cavity walls, Loft and Floor.Size of area to be heated (in meters) including the Length, Width, and Height: Single, Double or Triple Glazing and whether it is wood, metal or PUVC.Here is a list of the causes of heat loss which should be considered: There are many causes of heat loss that MUST be considered for EVERY ROOM, and an online calculator MUST ask about all of them, to be able to give you an accurate KW electric radiator size.

    heating load per m2 thumb

    Will the answer be the same? Can the algorithm know how many forms of heat loss are in each of your rooms? If your room sizes are the same, will the KW output needs of each radiator be the same – without knowing how many doors and windows are in each separate room? Room Size minus causes of heat loss Suppose you live in an apartment with a flat below or above. But does an average house have cavity wall insulation? Double glazing? Floor insulation? Loft insulation? semi detached property? And are you SURE that you live in an average house? Is there a specification for what they deem to be average? So which one will give you the right answer? Will they all give the same answer? How can you decide which one to trust with the comfort of your whole family for the next ten years?Įvery online radiator size calculator is just an algorithm that will give you an average-ball-park calculation if you live in an average house. They all ask different questions, request different measurements and ask you to confirm different basic parameters. Online Heating KW CalculatorĪ quick internet search will show you many online calculators to use, but guess what? They are ALL DIFFERENT. Perhaps you have chosen a 1,5 KW radiator and you are now wondering if it is enough to heat your size of each room? If is the correct dimensions, or perhaps you have rooms of an average 12 square meter size and need to know the correct output you need to heat each room.

    HEATING LOAD PER M2 THUMB HOW TO

    Choosing your new or replacement heating system is stressful enough, without worrying about how to choose the correct size of Electric Radiator for every room. IntelliHeat step-by-step method, how to buy the right size & power Electric Radiators for each room. Leaky building 0.6 CFM/sq.ft.Simple Guide for Calculating Heating KW Per Room. Heating Infiltration (15-mph wind) Air Change Rate Method Winter sensible infiltration loads will generally be 1/2 to 3 times the conduction heat losses (average 1.0 to 2.0 times).

    heating load per m2 thumb

  • Buildings that are not humidified have no latent infiltration heating load.
  • Below Grade or Interior Spaces-No infiltration losses or gains are taken for rooms located below grade or interior spaces.
  • The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS).






    Heating load per m2 thumb